founding seam + Go: the device plan carries each machine's PLACE and its CONNECT FACTS — a plan of machines nobody has reached #1416
Labels
No labels
agent-blocked
agent-working
autopilot
bug
deferred
deploy-pending
enhancement
landing-pr
model-haiku
model-opus
model-sonnet
needs-design
needs-info
needs-triage
no-triage
out-of-scope
priority
ready-for-agent
ready-for-human
ready-for-session
rehearsal-183
snapshot-pending
standing-drive
wayfinder:grilling
wayfinder:map
wayfinder:prototype
wayfinder:research
wayfinder:task
wontfix
No milestone
No project
No assignees
2 participants
Notifications
Due date
No due date set.
Blocks
Depends on
Reference
Matou/idss#1416
Loading…
Add table
Add a link
Reference in a new issue
No description provided.
Delete branch "%!s()"
Deleting a branch is permanent. Although the deleted branch may continue to exist for a short time before it actually gets removed, it CANNOT be undone in most cases. Continue?
Why
DDR 0241. #1391 made the device plan seam truth —
Draft.Placement{devices, where}withPlacementDevice{id, name, kind, mem_mb, mem_source, gateway}, server-checked against the 80% ceiling. What it does NOT carry is what DDR 0240 now reads off each machine at selection, and without that the plan describes machines the build cannot reach.What to build
PlacementDevicegains the device's identity and its connect facts: which place it lives in (rented/own-vps/self-hosted), its address or location, and theDeviceFactsread at connect (#1413) — host, os, arch, cores, mem, disk, SSH host key.mem_sourceflips tomeasuredoff that read rather than off pairing, andorderedsurvives only for a rented machine that does not exist yet.save-placementrefuses a plan carrying a machine that was never connected (the rented exception aside), the same way it already refuses an over-ceiling drop.Acceptance criteria
save-placementrefuses an unconnected non-rented machine, naming it, and leaves the draft unchanged.Contract
DDR 0241 decisions 1, 2 and 6; DDR 0240 decision 5; builds on #1391 (merged to
main, not yet onfounding-ui-two-colour-rail-ceremony).Triage Notes
Routing:
needs-design(missing-design gate).What we've established:
docs/adr/— the highest-numbered record is0239-design-the-coa-first-founding-branch-and-the-bring-it-home-walk.md, and no doc in the repo even references 0240/0241. The design-tier contract the agent would build against hasn't been produced yet.needs-design; #1391 and #1392 are closed/merged.Why
needs-design, notready-for-agent: the design-to-agent missing-design gate routes any issue whose referenced design contract (flow / wireframe / seam / design DDR) is missing or unconfirmed back to the design tier (grill-ux-with-docs/wireframe/ DDR authoring) for this feature before implementation. The acceptance criteria here are anchored to specific DDR decisions, so an agent cannot build against them until 0240/0241 land.This is a deterministic gate check, not an ADR 0174 judgement call — fully revertible by relabelling once the DDRs are written and confirmed. No human residue.
To unblock: author DDR 0240 and DDR 0241 (the founding-v2 device-plan / selection-proves-the-device decisions), then relabel for the normal pipeline.
Build reference + the TS half this ticket also owns
Go (
internal/founding/placement.go, on main):PlacementDevicegainsplace (rented|own-vps|self-hosted),ip,preset+region(rented only — what the buildrents, DDR 0237 decision 8),
facts DeviceFacts,checks_passed.mem_source:orderedfor rented (preset),measuredofffacts.mem_mbotherwise.SavePlacementjoins the facts #1413 held by NAME and refuses a non-rented machine with none
(
ErrPlacement, named).The renderer drops exactly this today, so the seam would receive a plan it cannot build:
FoundingDevicePlacement.vue:314-326 onPlannedkeeps onlyname/kind/memMb/locationfrom
PlannedDevice{place, preset, region, memMb, price, ip, location}(
adddevice/addDevice.ts) — carryplace,ip,preset,regiononto the bench'sPlacementDevice(devicePlacement.ts:23).FoundingJourney.vue onPlacementContinuestampsmemSource:'measured'for ANYmemMb— a rented device isordered.FakeFoundingClient.savePlacement(founding.ts:3429) accepts anything; make itrefuse an unconnected non-rented device the way
validatePlacementwill.Drop this ticket's "Review and the S12 hand-off enumerate the FLEET" bullet: that is T1.
Amended by the review fixes (2026-09-12)
The TS half named above is DONE:
PlacementDevice(both the seam's and the bench's — one type now,devicePlacement.tsextends the seam's) carriesplace,ip,preset,region,memSource: 'ordered' | 'measured';onPlannedkeeps them;onPlacementContinuesends the bench's device as-is and holds the plan only aftersave-placementsucceeds. Go'splacement.go(onmain) has to grow the same fields — that is what is left here, plus joining the facts #1413 holds by name.Label
needs-designstays untilfounding-ui-two-colour-rail-ceremonymerges tomain: the DDRs, the frames and the TS half this ticket builds against live on that branch, and a swarm worker builds frommain. At the merge, flip toready-for-agent— nothing else gates it.The branch merged to
main(fcf1c5b2): DDR 0240/0241, the S4d/S1c frames and the built TS half are onmainnow, soneeds-designcomes off and this isready-for-agent— gated only by its native dependencies.swarm-claim host=matou-dev-server-01 run=22596
(automated multi-host claim — lowest live claim id works this ticket)
swarm-claim host=matou-dev-server-01 run=22601
(automated multi-host claim — lowest live claim id works this ticket)
close-report for #1416 — status
success✅ close-report gates passed — every claim verified against main; issue closed.
envelope
journey.rented-device.spec.tson the standing rented community: Overview → Add a device → place → rent → the box calls in → the device card → remove → reap; GREEN is the only close #1400