panel-unlock: the phone unlock is INERT in production — the shell never wires a handover port, so a steward who approves the unlock line still types their twelve words #1958
Labels
No labels
agent-blocked
agent-working
autopilot
bug
deferred
deploy-pending
enhancement
landing-pr
model-haiku
model-opus
model-sonnet
needs-design
needs-info
needs-triage
no-triage
out-of-scope
priority
ready-for-agent
ready-for-human
ready-for-session
rehearsal-183
snapshot-pending
standing-drive
wayfinder:grilling
wayfinder:map
wayfinder:prototype
wayfinder:research
wayfinder:task
wontfix
No milestone
No project
No assignees
1 participant
Notifications
Due date
No due date set.
Dependencies
No dependencies set.
Reference
Matou/idss#1958
Loading…
Add table
Add a link
Reference in a new issue
No description provided.
Delete branch "%!s()"
Deleting a branch is permanent. Although the deleted branch may continue to exist for a short time before it actually gets removed, it CANNOT be undone in most cases. Continue?
Parent
What to build
The panel's headline behaviour does not work on main.
MembersSurfacetakes an optionalhandoverport and falls back toinertHandoverPort; the shell's mount registry spreads its members deps into that component and never constructs a handover port at all — a grep forhandoveracross the registry, the deps andboot/finds nothing. So in production the port is always the inert one, whosesignInArmed()returnsfalseand whoserequestHandover()returns{ kind: 'none' }.The result: a steward signs in through the app door with the unlock line on, the wallet seals their passcode and the bridge relays it — and the panel never asks for it. It renders PU-M0, locked, and the steward types their twelve words. Everything ADR 0282 promised is in place except the one call that collects it.
The door side already exists (#1933): a panel sign-in code carries
ek=, the present route accepts the sealed box, and the status poll hands the ciphertext over once. This ticket wires the panel to it — the shell builds a real handover port over the bridge's existing status poll and passes it down, so the sign-in-armed path completes.The fresh-unlock path (PU-M0q's code after a reload) needs a door route that does not exist; that is its own ticket, filed beside this one.
Why nothing caught it
The unit tests inject a fake port, so they are honestly green. The twelve-words fallback means a human sees a working panel, just a chattier one. And
inertHandoverPort's own docstring says "Production passes a real port down from the shell" — describing an intention that was never built. Note for #1940: gate 6 (binds) would not catch this, because the symbol is bound — to an inert default. A binding that silently does nothing is invisible to it.Acceptance criteria
inertHandoverPortremains only as a test/default and is not what production runs.Blocked by
None — can start immediately. The door side landed in #1933.
Task manifest
Filed 2026-09-28 after checking the panel-unlock feature against
origin/main: the phone unlock is inert in production. Verified with Ben before filing.🤖 Generated with Claude Code
https://claude.ai/code/session_015es4bpK4qRqZhrRYQBWCiY
Closing as a duplicate of #1957, which a swarm agent filed at 05:49 — six minutes before this one and with the same evidence (
handoverPort.ts:70,MembersSurface.vue:348, the shell never constructing a port). Theirs additionally traces it to a tail #1934 declared and nobody filed.The parts of this ticket that were not in #1957 — the gate-6 observation, the user-visible statement of the bug, and two criteria beyond the happy path — are carried over as a comment there. #1959 (the missing unlock route) now depends on #1957 instead of this.
No work is lost; this number is just redundant.